英國Cussons快速空氣燃油比分析系統(tǒng)P1300\P1301

價(jià)  格:詢價(jià)

產(chǎn)  地:英國更新時(shí)間:2020-10-29 10:38

品  牌:Cussons型  號:P1300\P1301

狀  態(tài):正常點(diǎn)擊量:2410

400-006-7520
聯(lián)系我時(shí),請說明是在上海非利加實(shí)業(yè)有限公司上看到的,謝謝!

上海非利加實(shí)業(yè)有限公司

聯(lián) 系 人: 上海非利加實(shí)業(yè)有限公司

電   話: 400-006-7520

傳   真: 400-006-7520

配送方式: 上海自提或三方快遞

聯(lián)系我時(shí)請說在上海非利加實(shí)業(yè)有限公司上看到的,謝謝!



Fast Response Time with High Accuracy
Automatic Range Change and Calibration
Operation on all HC and Alcohol Fuels
Externally Controllable
Built-in Statistical Functions
Heated Sampling for Durability and Accuracy
Wide Sample Pressure Tolerance
GPIB (IEEE 488) Interface as Standard
Simple to Operate, with Pre-set Programs 

Microprocessor Based


產(chǎn)品參數(shù)

MEASUREMENT RANGE:5–50 AFR by four steps. Automatic range change mode selectable

ACCURACY:± 0·04% volume of O2 which is typically equivalent to better than ± 0·1 AFR, ± 0·005l
STABILITY:Better than ± 0·02% volume O2 over 2 hour measurement period
RESOLUTION:± 0·01% volume O2, ± 0·01 AFR, ± 0·001l
REPEATABILITY:Better than ± 0·02% volume O2. Typically equivalent to better than ± 0·05 AFR, ± 0·003l
LAG TIME WITH 3M HEATED LINE:Less than 500 milliseconds
RESPONSE RISE TIME WITH 3M HEATED LINE: Air to Nitrogen; 90% change in less than 300 milliseconds without digital frequency compensation.

EXHAUST SAMPLE INLET PRESSURE; TOLERANCE :–200 mbar to +1 bar, resulting ± 0·003l at low dope, ±
0·01l at high dope
EXHAUST SAMPLE FLOW::Approximately 5 litres per minute
EXHAUST SAMPLE TEMPERATURE:For 0o to 400oC use Models P9121 of P9123  For –40o to 100oC use Models P9116/7 or P9124
WARM UP TIME:60 minutes
TYPICAL CATALYST LIFE:500 hours unleaded fuel, 50 hours leaded fuel
AMBIENT TEMPERATURE:0 to 50oC
RECORDER OUTPUTS (STANDARD) :0 to 1V = 0 to full scale for l/AFR/O2 ;0 to 1V o 0 to 10% O2
COMPUTER INTERFACE:GPIB (IEEE 488) standard
HC RATIO ADJUSTMENT RANGE :0·00 to 9·99
OC RATIO ADJUSTMENT RANGE :0·00 to 9·99
HEATED SAMPLE LINES :3 metres length standard, 1, 5, 8 or 10 metres, options directly interchangeable
CONNECTING CABLE - CONTROL UNIT TO
SAMPLE HANDLING UNIT :17 way x 6 metre long. Other lengths 1 to 25 metres to order
SAMPLE FILTER :19 mm x 90 mm Whatman extraction thimble
ELECTRICAL POWER REQUIREMENTS :Single Phase, 2·8kW, 100-120/200-240V, 50/60Hz
GAS SUPPLIES
Purge Air 10 litre/mm at 2 to 6 bar
N2 Zero Gas 5 litre/mm at 2 to 3 bar
O2/N2 Cal Gas 5 litre/mm at 2 to 3 bar


產(chǎn)品介紹

The value of the fast response measurement of Air-Fuel ratios (AFR) has long been appreciated in the study of both
fuel delivery systems and in-cylinder combustion processes.
The CUSSONS Lamdascan principle is a well established one. Exhaust sample gas is taken from a source, passed through a heated sample line and diluted with an accurately metered quantity of ‘dope’ gas, which is usually ambient air. The diluted sample is oxidised over a platinum catalyst and passed to a high temperature zirconia cell. Residual oxygen, which is directly proportional to the engine AFR and the known quantity of dope gas, is measured by the zirconia cell.
Bottled gases (oxygen and nitrogen) may be used in place of the dope air when it is considered that the ambient air is sufficiently contaminated with carbon monoxide or hydrocarbons to cause inaccurate measurement.
Heated sampling prevents condensation of any hydrocarbon compounds and water vapour, and so increases accuracy and durability. 

Statistical functions (Average Value, Standard Deviation, and Peak to Peak), are obtained over a 30 second sampling
time, and are shown as the Equivalence Ratio (Lambda), or Air-Fuel Ratio, dependent upon display selected.
Automatic range change by dope gas switching ensures that the zirconium cell is operating at optimum oxygen concentration, and thus at best accuracy. AFR results from 5:1 to 50:1 may be obtained without loss of test data. Range changes may also be selected manually.
The GPIB (IEEE 488) is a standard feature which suits most forms of computer interface, and permits several Lamdascan sample handling units to be controlled from one master Lamdascan control unit. This feature is particularly useful for investigating transient mixture distributions.
Pre-set programs are selectable by positive action push button switches. The hinged front panel of the controller opens to allow access to switches for hydrogen/carbon (HC) and oxygen/carbon (OC) ratios of the fuel used, oxygen/nitrogen ratios of dope and reference gas - normally air, and external analogue signal zero and span settings.

Critical pressures are displayed on gauges on the sample handling unit to allow monitoring of correct operating conditions.




關(guān)于我們客戶服務(wù)產(chǎn)品分類法律聲明
主站蜘蛛池模板: 免费又黄又粗又爽大片69 | 殴美毛片| 久久福利 | 九九国产 | 四虎成人网 | 又大又黄又爽视频一区二区 | 日韩在线一区二区三区四区 | 日韩国产一区 | 亚洲自拍偷拍网站 | 一级毛片在线免费观看 | 精品国产一区二区三区久久久 | 成人污污www网站免费丝瓜 | 色图av| 伦理一区二区三区 | 一区二区三区四区国产精品视频 | 91探花国产综合在线精品 | 国产精品一区二区三区在线播放 | 成人午夜视频在线观看 | 国产精品99在线观看 | 日韩在线视频精品 | 成人网免费视频 | 亚洲xx站| 欧美色图在线观看 | 五十路少妇 | 成人毛片免费在线观看 | 欧美日韩第一页 | 在线视频 亚洲 | 在线观看黄色网页 | 日韩在线一区二区三区四区 | 51久久成人国产精品 | 搞j网站| 亚洲一区在线看 | 国产成人亚洲在线观看 | 欧美爱爱网址 | 色777狠狠综合秋免鲁丝 | 狠狠干影视 | 久久99久久99精品蜜柚传媒 | 三级伊人 | 插菊综合网 | 五月天综合网 | 国产欧美一区二区三区精品观看 |